Industry Solution · Urban Demolition
Urban Demolition Blasting Vibration Monitoring Solution
Safety assessment of nearby buildings & pipelines — evidence to prevent disputes

The seconds of a building, chimney, cooling-tower or city-bridge demolition blast are watched by the whole city. Collapse vibration superimposed on blast vibration, protected objects within meters, media and regulators all present — a zero-error-margin scenario. ZKCK provides urban demolition with synchronized multi-point monitoring and data fit for the courtroom.
Pain PointsPAIN POINTS
Metro tunnels, underground pipelines, retained buildings, ancient trees and bridges — often only tens of meters from the blast, each with different allowable velocity.
Both explosive vibration and ground-impact collapse vibration of tall structures — timing and spectra must be separated clearly.
Police, owner, supervisor and resident representatives are watching — reports must be available on site.
A demolition blast cannot be repeated — the monitoring system must be fail-safe.
Reference StandardsSTANDARDS
Demolition vibration criteria and collapse-vibration control
Blasting project filing, safety assessment and supervision requirements
Key ChallengesCHALLENGES
Points scattered across retained-building foundations, directly above underground pipelines and over metro-tunnel crowns — synchronized triggering on a common time axis is required.
Collapse vibration is low-frequency and energetic, strongly affecting nearby shallow-foundation buildings.
Complex on-site electromagnetic environment (blasting machines, broadcast equipment) — instruments must resist interference.
SolutionsSOLUTION
6850 / 4850N series
4G · WiFi · LAN
Alarm · Reports · Regulator upload
TC-4850-6
6 channels in one unit
Industry-exclusive 6 parallel channels accepting two triaxial sensors at once — one deployment covers more protected objects; ≈1 TB storage, record length 1–5590 s adjustable
TC-4850N-3
Real-time online at key points
4G full-network real-time upload to the cloud; owner/supervisor view data remotely in sync; characteristic-value report auto-pushed after triggering
Recommended combination: TC-4850-6 (multi-point host) + TC-4850N (remote backup & real-time upload)
Deployment & ParametersDEPLOYMENT
Deploy by "nearest protected object first": one triaxial set each on retained-building foundations, above pipeline axes and directly over the metro tunnel; add a control group at the outer edge of the collapse zone.
Pre-set trigger levels below the strictest allowable value (0–10 V freely adjustable) — better safe than sorry.
The TC-4850-6 acquires with two triaxial sensors in sync plus vector-composition analysis, directly yielding three components and the principal vibration direction.
After the blast, a POS printer outputs the event report on site for police-witnessed sign-off; full reports batch-export via cloud to Word/PDF and are archived the same day.
Why ZKCKWHY ZKCK
One TC-4850-6 does the work of two — simpler cabling and coordination.
Sectioned analysis + frequency spectra yield characteristic values for blast and collapse segments separately.
POS on-site printing + mini-program reports — seamless data flow under multi-party witness.
Legally valid data — solid basis for disputes and claims.
TC-4850 Blasting Vibration MeterPortable · Self-adaptive range · Fast deploymentView details →
TC-4850N Network Vibration Meter3/6 channels · Solar + battery · Long-term onlineView details →
6850 Integrated Network VibrometerVelocity + acceleration · Only 560g · OLED displayView details →More Solutions
- Section: Solutions
- Platform: ZKCK Cloud (Online Monitoring)