Standard of Vibration in Urban Area Environment

Zhongke Instruments · News2019-12-23 15:08:11

Home/News/Standard of Vibration in Urban Area Environment
Content

(Approved by the National Environmental Protection Administration on December 10, 1988 Implemented on July 1, 1989)

 

1 Subject Content and Scope of Application 

This standard is formulated to implement the Environmental Protection Law of the People's Republic of China (Trial) and to control vibration pollution in the urban environment. 

This standard specifies the standard values of vibration in urban area environment, the applicable zone ranges and the monitoring methods. 

This standard applies to the urban area environment. 

2 Cited Standards 

GB 10071 Measurement Method of Vibration in Urban Area Environment 

3 Standard Values and Applicable Zone Ranges 

3.1 Standard Values 

3.1.1 The standard values of vertical Z vibration levels for various urban zones are listed in the table below.

 

Applicable Zone Range 

Daytime 

Nighttime 

Special Residential Zone 

65 

65 

Residential and Cultural-Educational Zone 

70 

67 

Mixed Zone and Commercial Center Zone 

75 

72 

Industrial Concentration Zone 

75 

72 

Both Sides of Main Traffic Arteries 

75 

72 

Both Sides of Main Railway Lines 

80 

80 

 

3.1.2 These standard values apply to continuous steady vibration, impact vibration and random vibration. 

3.1.3 For impact vibrations occurring several times a day, the maximum value shall not exceed the standard value by 10 dB in the daytime and by 3 dB at night. 

3.2 Delineation of Applicable Zone Ranges 

3.2.1 The special residential zone refers to a residential area that particularly requires quietness. 

3.2.2 The residential and cultural-educational zone refers to an area of purely residential, cultural-educational and government institutions. 

3.2.3 The mixed zone refers to an area mixing general commerce with residence, or mixing industry, commerce, a small amount of traffic with residence. 

3.2.4 The commercial center zone refers to a prosperous area with concentrated commercial activities. 

3.2.5 The industrial concentration zone refers to an industrial area clearly designated in the planning of a city or region. 

3.2.6 Both sides of main traffic arteries refer to the two sides of roads with a traffic flow of more than 100 vehicles per hour. 

3.2.7 Both sides of main railway lines refer to the residential areas beyond 30 m on both sides outside the outer rail of railways with a daily traffic of no fewer than 20 trains. 

3.2.8 The applicable zone ranges of this standard shall be delineated by local people's governments. 

3.3 The daytime and nighttime hours of this standard shall be delineated by the local people's government according to local habits and seasonal changes. 

4 Monitoring Methods 

4.1 The measuring point shall be located at a vibration-sensitive spot within 0.5 m outside the building; if necessary, the measuring point shall be placed at the center of the indoor floor of the building; the standard values shall be taken from the table. 

4.2 The measurement of the vertical Z vibration level and the calculation of evaluation quantities shall be carried out in accordance with the relevant provisions of the national standard GB 10071. 

Additional Explanations: 

This standard was proposed by the Air Pollution Control Department of the National Environmental Protection Administration. 

This standard was drafted by the drafting group of the Standard of Vibration in Urban Area Environment. 

The main drafters of this standard are Zhan Jiakai, Chen Daochang, Tang Ruirong, Xiong Guangling and Tu Ruihe. 

This standard is interpreted by the National Environmental Protection Administration.

 

For more information, please consult our customer service staff. Blasting vibration monitoring Blasting vibration standards 

Download:GB 10070-1988 Standard of Vibration in Urban Area Environment