Tel: 13088055927 / 028-85238246
Summary: The TC-4850 blasting vibration meter developed by Chengdu Zhongke Chuankong (ZKCK) measures the vibration velocity and frequency at the monitored point during blasting. It can be used for blasting vibration monitoring and environmental safety assessment in various projects such as dams, bridges, tunnels, railways and highways, as well as various vibration monitoring in similar fields. It is also suitable as experimental teaching equipment for related majors in universities.

Dongfang Turbine Plant Dynamic Balancing Vibration Case

Video: http://v.ku6.com/show/_j3WFfNTRs-CR9QE6i5eYQ...html?loc=youce_tuijian

 

Site conditions and environment

Dongfang Turbine Co., Ltd., successor of the Dongfang Turbine Works, is among China's top-100 machinery enterprises and one of the three major turbine manufacturing bases. To expand new business, the company planned a 350 t high-speed dynamic balancing test station on an open plot in the plant. However, the plot adjoins National Highway G108 with many heavy trucks, whose passage causes obvious vibration on the plot. To prevent long-term vibration affecting the building, they contacted us to test whether the low-frequency vibration is within the building design tolerance and to compare vibration levels of two siting options.

    

Both test sites are south of the nuclear power workshop in the Dongfang plant area near the G108/Jianghan Road intersection, each 16.5 m wide and 20.74 m long (see Attachments 1 and 2), on plant lawn essentially level with the highway and workshop. Site geological survey shows the top 1 m is mainly silt.


Test purpose

Per Dongfang Turbine's requirement - "foundation vibration for power machinery base and dynamic balancing tests: foundation amplitude ≤7.5 (vertical, lateral), ≤5 (longitudinal, along the vacuum chamber), foundation vibration velocity ≤5 mm/s (all directions)" - the test used triaxial low-frequency velocity sensors to measure velocity, integrated to displacement, estimating the impact of passing heavy vehicles on the foundation of the 350 t high-speed dynamic balancing test station.


Result evaluation and analysis

Among all valid data, the maximum vibration velocity was 0.64 mm/s, meeting the ≤5 mm/s (all directions) foundation velocity standard; maximum displacements were 26.7 (X), 33.1 (Y) and 23.3 (Z), exceeding the amplitude requirements of ≤7.5 (vertical, lateral) and ≤5 (longitudinal, vacuum chamber direction).

Of these, 32 sets of over-limit X displacement (>5) and 37 sets of Y/Z displacement (>7.5) were recorded; 62 of the 69 over-limit sets were measured at 13:07 on April 1, 2011, mainly caused by an earthquake (confirmed by the China Earthquake Networks Center: a 4.0-magnitude quake at Mianzhu, Deyang, Sichuan, 31.6N 104.0E, depth 22 km, at 13:07 that day). The other over-limit sets: Site 1 - X (5.3, 7.3, 7.5) 3 sets, Z (7.7) 1 set; Site 2 - X (5.1, 6.1, 6.2) 3 sets. These marginal values have little impact on either site.

Comparison: Option 1 (Site 1) vs Option 2 (Site 2)

    Under identical instrument settings, Site 2 yielded far more valid data sets (979) than Site 1 (601), indicating Site 2 suffers more vibration - mainly because heavy trucks often pass nearby.