中文

News

Interpreting Blasting Vibration Data: Why Peak Particle Velocity and Frequency Must Be Evaluated Together - Blasting Vibration Meter

Zhongke Instruments · News2026-10-23 09:00:00

Home/News/Interpreting Blasting Vibration Data: Why Peak Particle Velocity and Frequency Must Be Evaluated Together - Blasting Vibration Meter
Content

1. Can peak velocity alone be misleading?

Many monitoring reports contain a single-line conclusion: the maximum peak particle velocity of this blast was X.XX cm/s, below the limit, therefore safe. This is not rigorous in low-frequency scenarios. The same 2 cm/s peak velocity carried by a 2 Hz long-period wave and by a 40 Hz high-frequency wave produces completely different structural responses - low-frequency components are close to the natural frequencies of ordinary buildings and can amplify resonance, doing far more damage. Standards at home and abroad therefore no longer rely on a single velocity criterion.

2. The logic of the combined criterion in GB 6722-2014

In the Safety Regulations for Blasting (GB 6722-2014), the permissible peak particle velocity for ground structures is given in tiers by building type and vibration frequency band - a combined velocity-frequency criterion: the lower the dominant frequency, the stricter the permissible velocity. In assessment, the measured dominant frequency must be placed in its corresponding band and compared against that band's limit, rather than applying the most permissive limit across the board. For the exact limits, refer to the official text of the standard.

3. How to acquire reliable field data

1) Sensors must be firmly coupled: bond with plaster or epoxy on hard surfaces, bury and backfill compactly on soil - loose placement severely attenuates peaks;
2) Always measure in three components: record vertical, radial and transverse separately and evaluate using the largest of the three - single vertical-axis measurement misses results;
3) Match sampling rate and range: the sampling rate should be at least 10 times the upper frequency of interest, and the range should be chosen to avoid clipping;
4) Record complete time histories: instruments that store only peak values cannot perform spectral analysis, cannot yield a dominant frequency, and therefore cannot support a proper assessment.

4. Conclusion

Peak velocity tells you how strong the vibration is; dominant frequency tells you whether it can be filtered out by structural response. Together they determine safety. Choosing a blasting vibration meter that supports three-component measurement, complete spectral analysis and the combined GB 6722-2014 assessment procedure is the precondition for reliable conclusions. For technical support with monitoring plans and sensor placement, contact Chengdu Zhongke Measurement and Control.

Why Choose ZKCK

30 years in the industry · CPA-certified quality · stable equipment, no dropouts · 2-year warranty with free repair · free platform integration