Blasting Vibration Safety Permissible Standards - Blasting Vibration Safety Permissible Distances

Zhongke Instruments · News2015-04-09 17:07:56

Home/News/Blasting Vibration Safety Permissible Standards - Blasting Vibration Safety Permissible Distances
Content

Blasting vibration safety permissible standards - blasting vibration safety permissible distances - use a blasting vibrometer to monitor vibration data for judgment

                               Blasting Vibration Safety Permissible Standards

No.

Category of Protected Object

Safety Permissible Vibration Velocity (cm/s)

<10 Hz

10 Hz~50 Hz

50 Hz~100 Hz

1

Earthen cave dwellings, adobe houses, rubble stone houses a

0.5~1.0

0.7~1.2

1.1~1.5

2

Ordinary brick buildings, non-aseismic large block buildings a

2.0~2.5

2.3~2.8

2.7~3.0

3

Reinforced concrete structure buildings a

3.0~4.0

3.5~4.5

4.2~5.0

4

Ordinary ancient buildings and historic sites b

0.1~0.3

0.2~0.4

0.3~0.5

5

Hydraulic tunnels c

7~15

6

Mine roadways x

10~20

7

Traffic tunnels c

15~30

8

Hydropower station and power plant central control room equipment c

0.5

9

Newly poured mass concrete d:

Age: initial setting to 3 d

Age: 3 d to 7 d

Age: 7 d to 28 d

 

2.0 ~3.0

3.0~7.0

7.0~12

Note 1: The frequencies listed in the table are the dominant vibration frequencies, referring to the wave frequencies corresponding to the maximum amplitudes.

Note 2: The frequency range can be selected based on similar projects or measured on-site waveforms. When selecting frequencies, the following data can also be referenced: chamber blasting <20 Hz; deep-hole blasting 10 Hz to 60 Hz; shallow-hole blasting 40 Hz to 100 Hz.

a When selecting the building safety permissible vibration velocity, factors such as the importance of the building, construction quality, degree of newness, natural frequency and foundation conditions should be comprehensively considered.

b The safety permissible vibration velocity of key protected ancient buildings and historic sites at or above the provincial level shall be selected through expert demonstration and reported to the corresponding cultural relics administration department for approval.

c When selecting the safety permissible vibration velocity for tunnels and roadways, factors such as the importance of the structure, surrounding rock conditions, cross-section size, burial depth, blast source direction and seismic vibration frequency should be comprehensively considered.

d The safety permissible vibration velocity of non-water-retaining newly poured mass concrete may be selected according to the upper limit values given in this table.

 

6.2.3   The blasting vibration safety permissible distance can be calculated by Formula (1).

       (1)

Where:

R - blasting vibration safety permissible distance, in meters (m);

Q - explosive quantity, the total charge for simultaneous blasting, the maximum per-delay charge for delay blasting, in kilograms (kg);

V - the safety permissible vibration velocity of the particle at the location of the protected object, in centimeters per second (cm/s);

K、 - the coefficient and attenuation exponent related to the terrain and geological conditions between the blasting point and the calculated protected object, which can be selected from Table 5 or determined through field tests.

Table 5  K and a Values for Different Rock Properties in the Blasting Zone

Rock Property

K 

a

Hard rock

50~150

1.3~1.5

Medium-hard rock

150~250

1.5~1.8

Soft rock

250~350

1.8~2.0

For multi-charge group blasting, when the difference between the distances of each charge to the protected target exceeds 10% of the average distance, the equivalent distance Re and equivalent charge Qe are used to replace R and Q respectively. The calculation of Re and Qe adopts the weighted average method.

For cylindrical (strip) charges, the strip charge can be divided into multiple concentrated charges at 1 to 1.5 times the minimum burden length, and the equivalent distance and equivalent charge can be calculated with reference to the method for multi-charge group blasting.

6.2.4   For the blasting vibration safety standards of general protected objects not covered in 6.2, they can be proposed through design demonstration with reference to the provisions of 6.2; for particularly

important protected objects, the safety criteria and permissible standards shall be proposed through expert demonstration.

The safety permissible distance for urban demolition blasting is determined by the design.

6.2.5  When blasting near special buildings (structures) or in areas with complex blasting conditions, necessary blasting vibration monitoring or special tests shall be carried out to ensure the safety of protected objects

6.2.6  When blasting operations are carried out multiple times in complex environments, one should start from the single-shot charge quantity that ensures safety, gradually increase to the permissible charge quantity, and control the scale of each blasting according to the permissible charge quantity.