Piling Vibration Monitoring 5 m Underground
Monitoring Scene
Success case
Instrument
TC-4850
Category
Case Studies
Piling vibration monitoring 5 m underground
capacity 16G
Contact: 13088055927 / 028-85238246
Summary: The TC-4850 blasting vibration meter developed by Chengdu Zhongke Chuankong measures the peak particle velocity and frequency of ground vibration at monitoring points during blasting. It is suitable for vibration monitoring of dam, bridge, tunnel, railway and highway blasting projects, environmental safety assessment of blasting operations and vibration monitoring in similar fields, and can also serve as teaching equipment for related university courses.
In early June 2016, technicians of Chengdu Zhongke Chuankong brought 5 self-developed waterproof triaxial low-frequency sensors to a site in Shenzhen to monitor the impact of piling vibration on a nearby drinking-water box culvert.
Based on site conditions, our technicians developed a monitoring plan with the client: 5 monitoring points were laid out in a straight line between the piling rig and the box culvert, from near to far. For more accurate monitoring, the 5 sensors were buried 5 m underground (the most sensitive depth for the culvert), and the burying holes were compacted for realistic data.
After the sensors were buried, the piling rig started working and vibration monitoring began. The low-frequency sensors transmitted vibration signals to the TC-4850 monitor, which acquired data at all 5 points simultaneously for each vibration event; we also recorded vibration intensity produced by the hammer dropping from different heights.
Through repeated data acquisition, we clarified the impact of different piling methods on the box culvert, providing valuable data for future construction plan design.

Waterproof triaxial low-frequency sensor strapped to a PVC pipe

Buried 5 m underground

Vibration data then read with the TC-4850 vibration monitor