The blasting noise recorder developed by Chengdu ZKCK measures environmental noise induced by field blasting, for safety assessment and various monitoring in similar fields, and can also serve as experimental teaching equipment for related university majors. It complies with GB6722-2014 Safety Regulations for Blasting, fully satisfies blasting-industry qualification applications, with high-precision measurement.

Sensitivity

50 mV/Pa ( ±5% ) -26 dB re 1…

Frequency response

10 Hz-10 kHz ±1.5 dB; 20 Hz-…

Temperature coefficient

-10 to 50 ℃, -0.01 dB/℃ (250…

Operating temperature

-25 to 55 ℃

Enquire: 13088055927 / 028-85238246View all Sensors →

Key Specifications

Parameters below are extracted from this page; values and units are kept verbatim.

Sensitivity50 mV/Pa ( ±5% ) -26 dB re 1 V/Pa ( ±5% )
Frequency response10 Hz-10 kHz ±1.5 dB; 20 Hz-20 kHz ±3 dB; 1/2" IEC 61672 Class 1
Temperature coefficient-10 to 50 ℃, -0.01 dB/℃ (250 Hz)
Operating temperature-25 to 55 ℃
Pressure coefficient-0.01 dB/kPa (250 Hz)
Self-noise≤17 dB
Dynamic range upper limit133 dB Distortion < 3%
Diameter13.2 mm (with guard); 12.7 mm (without guard)
Height17.5 mm (with guard); 16.5 mm (without guard)
With 4850-3range 40-133 dB (microphones up to 180 dB optional)
Software analysisCovers steady, transient and impulse noise;
Time weighting5 ms-2000 ms user-input analysis, covering 35 ms/125 ms and 1 s time weightings

     A new instrument for blasting noise, environmental noise and various mechanical noise testing, compliant with GB/T3785 Type 2 and IEC 61672 Class 2 as well as Safety Regulations for Blasting (GB6722-2014).

The CHZ series electret condenser microphones cover 1-inch, 1/2-inch and 1/4-inch measurement microphones. With nearly 30 design and process improvements and strict quality control, the CHZ series offers the best acoustic performance and long-term stability among comparable domestic products.

The CHZ-211 microphone has a frequency response of 6.3 Hz-20 kHz ±2 dB, meeting the IEC 1094-4 WS2 frequency-response requirement - the best choice for high-precision acoustic measurement. Its low-frequency cutoff (-3 dB) is below 3 Hz, suitable for low-frequency noise testing.

▲ Sensor specifications

Sensitivity: 50 mV/Pa   ( ±5% )  -26 dB re 1 V/Pa  ( ±5% )

Frequency response: 10 Hz-10 kHz   ±1.5 dB; 20 Hz-20 kHz ±3 dB; 1/2" IEC 61672 Class 1

Temperature coefficient: -10 to 50 ℃, -0.01 dB/℃  (250 Hz)

Operating temperature: -25 to 55 ℃

Pressure coefficient: -0.01 dB/kPa   (250 Hz)

Self-noise: ≤17 dB

Dynamic range upper limit: 133 dB     Distortion < 3%

Diameter: 13.2 mm (with guard); 12.7 mm (without guard)

Height: 17.5 mm (with guard); 16.5 mm (without guard)

▲With TC4850-series acquisition units:

With 4850-3: range 40-133 dB (microphones up to 180 dB optional)

Software analysis:Covers steady, transient and impulse noise;

Time weighting:5 ms-2000 ms user-input analysis, covering 35 ms/125 ms and 1 s time weightings

Typical frequency-response chart

1668586944551140.jpg

1668586949192909.jpg

Sensor advantages

· 10 m signal cable with dedicated test bracket;

·With the noise adapter, it directly matches TC-4850/TC-4850N vibration meter main units.

· Noise sensors in different ranges available on demand.

1668587816530081.png