中文

News

"Standard for Appraisal of Dangerous Buildings" (JGJ 125-2016)

Zhongke Instruments · News2017-03-12 10:41:55

Home/News/"Standard for Appraisal of Dangerous Buildings" (JGJ 125-2016)
Content

1  General Provisions

1.0.1  This standard is formulated to effectively utilize existing buildings, accurately judge the danger degree of building structures, handle dangerous buildings promptly and ensure structural safety.

1.0.2  This standard applies to the danger appraisal of existing buildings with a height not exceeding 100 m.

1.0.3  In addition to complying with this standard, the appraisal of dangerous buildings shall also comply with relevant current national standards.

2  Terms and Symbols 

2.1  Terms

2.1.1  Existing building

A building completed more than two years ago and already in service.

2.1.2  Member

A basic unit composing the overall structure of a building - generally a single structural member bearing various actions, or a composite member composed of several bars or members.

2.1.3  Investigation

Information collection through site survey, document collection and review, etc.

2.1.4  Inspection

The examination, measurement and testing of the structural condition or performance of an existing building.

2.1.5  Assessment

The evaluation of the danger of an existing structure according to prescribed standards and methods, based on investigation, inspection and analytical calculation results.

2.1.6 Danger appraisal (appraisal)

A set of work activities aimed at judging the danger degree of the appraised building.

2.1.7  Dominant member

Members such as walls, columns, main beams and roof trusses whose own failure would cause the failure of other related members and endanger the safety of the load-bearing structural system.

2.1.8  Common member

Members such as secondary beams and floor slabs whose own failure would not trigger the failure of other members.

2.1.9  Dangerous member

A structural member whose bearing capacity, connection details, or damage indicators such as cracks, deformation, corrosion or insect damage fail to meet safe-use requirements.

2.1.10  Dangerous point

A structural member appraised as a dangerous member within the building structural system.

2.1.11  Dangerous building

A building whose structural system contains load-bearing members appraised as dangerous, causing parts or the whole to fail safe-use requirements.

Download:

icon pdf 4"Standard for Appraisal of Dangerous Buildings" (JGJ 125-2016).pdf