中文

News

"Technical Code for Monitoring of Building and Bridge Structures" (GB 50982-2014)

Zhongke Instruments · News2016-11-12 10:47:34

Home/News/"Technical Code for Monitoring of Building and Bridge Structures" (GB 50982-2014)
Content

1 General Provisions

1.0.1 This code is formulated to standardize the monitoring technology of building and bridge structures and the corresponding analysis and early warning, achieving advanced technology, reliable data and economic rationality.

1.0.2 This code applies to the monitoring of engineering structures such as high-rise and tall structures, long-span spaces, bridges and seismically isolated structures, as well as existing structures affected by undercrossing construction.

1.0.3 In addition to this code, the monitoring of building and bridge structures shall also comply with relevant current national standards.

2 Terms and Symbols

2.1 Terms

2.1.1 Structural monitoring 

Frequent or continuous observation or measurement of the structural state.

2.1.2 Construction-period monitoring 

Structural monitoring performed during construction.

2.1.3 Service-period monitoring 

Structural monitoring performed during the service period.

2.1.4 Monitoring system

The software and hardware integration of monitoring equipment realizing certain monitoring functions.

2.1.5 Monitoring equipment 

A general term for hardware such as sensors and data loggers in the monitoring system.

2.1.6 Transducer / sensor

A device that senses a specified measured quantity and converts it into a usable output signal according to certain rules, usually composed of a sensing element and a conversion element.

2.1.7 Monitoring frequency 

The number of monitoring sessions per unit time.

2.1.8 Monitoring precaution value

A warning value set for monitored quantities that indicate possible abnormal or dangerous states of the monitored object, to ensure structural safety or quality and the safety of the surrounding environment.

2.1.9 Monitoring system stability

The capability of the monitoring system to maintain normal performance after long-term use.

2.1.10 Monitoring equipment durability

The capability of monitoring equipment to still meet its intended functional requirements over time under normal use and maintenance conditions.