    In field blasting vibration monitoring, data acquisition for a single blast is non-repeatable - if the monitoring point is covered by the muck pile or the instrument is smashed by flyrock, no data can be obtained. Certain protective measures can shield sensors and recorders from external damage.

Common protective measures are as follows:

1   For monitoring points very close to the blast source that are prone to large flyrock, or important points, use small precast reinforced-concrete frames or retaining walls for protection; add steel plates on top for enhanced coverage if necessary;

2   For points expected to be affected only by small stones, use a metal box or, most commonly, a safety helmet for cover protection;

3   Other protective materials can be used: straw bags, straw curtains, bamboo fences, sandbags, rain cloth, woven bags, tinplate, dense safety nets, etc.;

4   To prevent accidental touching, insert flags or other obvious markers at monitoring points, or set up barriers, enclose with stones or bricks, cover with bamboo fences and straw bags. For important points, assign a dedicated watchman if necessary;

5   Some vibration velocity sensors have an inertial-mass lock. Before testing, set the lock to the unlocked position; re-lock after use to prevent fatigue or damage of the mass-spring system in the non-working state.